Product Name Catalog # Price   Qty
Human Cytokine ELISA Plate Array II (Chemiluminescence) EA-4019 $817
- +

Characterization

Description(s):

Cytokines are signaling molecules that have critical roles in many biological processes such as cellular growth, differentiation, gene expression, migration, immunity, and inflammation. Cytokines that are secreted from cells bind to cell-surface receptors, initiate the activation of signal transduction pathways and mediate cell to cell communication. The malfunction of cytokines leads to many diseases, including arthritis, acute and chronic liver disease, inflammatory bowel disease, cardiac-related diseases, and cancers. Cytokines are commonly working together in a biological or disease process. Therefore, the comprehensive analysis of the expression of multiple cytokines allows effective revealing of the underneath mechanism of cytokine action and the alteration leading to diseases. The Human Cytokine ELISA Plate Array is a chemiluminescent detection that allows you to monitor the abundance of 32 human cytokines simultaneously. This fast and sensitive assay can be used for quantitative comparison of these cytokines among different samples.

Detection Range:
    
2 - 2000 pg/mL

Sensitivity:
    
1 pg/mL


Applicable Grid:

List of Applicable Cytokines

  1 2 3 4 5 6 7 8 9 10 11 12
A CNTF IGF-BP1 IL-21 Neuroserpin CNTF IGF-BP1 IL-21 Neuroserpin CNTF IGF-BP1 IL-21 Neuroserpin
B CCL21 IL-3 IL-22 NOV CCL21 IL-3 IL-22 NOV CCL21 IL-3 IL-22 NOV
C CTGF IL-5 IL-31 CXCL12 CTGF IL-5 IL-31 CXCL12 CTGF IL-5 IL-31 CXCL12
D CXCL16 IL-7 CXCL11 TACI CXCL16 IL-7 CXCL11 TACI CXCL16 IL-7 CXCL11 TACI
E EG-VEGF IL-9 MIA-2 TIMP-1 EG-VEGF IL-9 MIA-2 TIMP-1 EG-VEGF IL-9 MIA-2 TIMP-1
F CXCL1 IL-11 Midkine TL-1A CXCL1 IL-11 MIP-1a Adipo IL-8 IL-12 MIP-1a Adipo
G CXCCL2 IL-17E CXCL9 TSLP CXCCL2 IL-17E CXCL9 TSLP CXCCL2 IL-17E CXCL9 TSLP
H ICAM-1 IL-20 CXCL7 TWEAK ICAM-1 IL-20 CXCL7 TWEAK ICAM-1 IL-20 CXCL7 TWEAK

Principle

The 96-well white plate is divided into 3 sections, and each section has 4 strips for one sample. In each section, 32 of specific cytokine capture antibodies are coated on 32 wells respectively, and one well without coating any antibody is used as a blank well.  The sample, such as cell culture supernatants, cell lysates, tissue homogenates, serum, or plasma samples is incubated with cytokine ELISA plate, and the captured cytokine proteins are subsequently detected with a cocktail of biotinylated detection antibodies. The test sample is allowed to react with pairs of two antibodies, resulting in the cytokines being sandwiched between the solid phase and enzyme-linked antibodies. After incubation, the wells are washed to remove unbound-labeled antibodies. The plate is further detected with HRP luminescent substrate. Luminescence is reported as relative light units (RLUs) on a microplate luminometer. The level of expression for each specific cytokine is directly proportional to the luminescent intensity.

Literature

View user manual