Product Name Catalog # Price   Qty
Human Cytokine ELISA Plate Array IV (Chemiluminescence) EA-4020 $817
- +

Characterization

Description(s):

Cytokines are signaling molecules that have critical roles in many biological processes such as cellular growth, differentiation, gene expression, migration, immunity, and inflammation. Cytokines that are secreted from cells bind to cell-surface receptors, initiate the activation of signal transduction pathways and mediate cell to cell communication. The malfunction of cytokines leads to many diseases, including arthritis, acute and chronic liver disease, inflammatory bowel disease, cardiac-related diseases, and cancers. Cytokines are commonly working together in a biological or disease process. Therefore, the comprehensive analysis of the expression of multiple cytokines allows effective revealing of the underneath mechanism of cytokine action and the alteration leading to diseases. The Human Cytokine ELISA Plate Array is a chemiluminescent detection that allows you to monitor the abundance of 48 human cytokines simultaneously. This fast and sensitive assay can be used for quantitative comparison of these cytokines among different samples.

Detection Range:
    
2 - 2000 pg/mL

 

Sensitivity:
    
1 pg/mL


Applicable Grid:

List of Applicable Cytokines

  1 2 3 4 5 6 7 8 9 10 11 12
A Adipo CXCL16 IGF IL-6 IL-22 PDGF-BB Adipo CXCL16 IGF IL-6 IL-22 PDGF-BB
B b-NGF EGF IGF-BP1 IL-8 IL-31 PIGF-1 b-NGF EGF IGF-BP1 IL-8 IL-31 PIGF-1
C CCL27 Exotaxin-3 IL-1a IL-10 IP-10 Rantes CCL27 Exotaxin-3 IL-1a IL-10 IP-10 Rantes
D CTGF FGFb IL-1b IL-11 Leptin Resistin CTGF FGFb IL-1b IL-11 Leptin Resistin
E CXCL1 G-CSF IL-2 IL-12 MCP-1 SCF CXCL1 G-CSF IL-2 IL-12 MCP-1 SCF
F CXCL2 GM-CSF IL-3 IL-13 MIP-1a TGFb CXCL2 GM-CSF IL-3 IL-13 MIP-1a TGFb
G CXCL9 ICAM-1 IL-4 IL-17a Neuroserpin TNFa CXCL9 ICAM-1 IL-4 IL-17a Neuroserpin TNFa
H CXCL11 IFNr IL-5 IL-17E PAI-1 VEGF CXCL11 IFNr IL-5 IL-17E PAI-1 VEGF

Principle

The 96-well white plate is divided into 2 sections, and each section has 6 strips for one sample. In each section, 48 of specific cytokine capture antibodies are coated on 48 wells respectively, and one well without coating any antibody is used as a blank well.  The sample, such as cell culture supernatants, cell lysates, tissue homogenates, serum, or plasma samples is incubated with cytokine ELISA plate, and the captured cytokine proteins are subsequently detected with a cocktail of biotinylated detection antibodies. The test sample is allowed to react with pairs of two antibodies, resulting in the cytokines being sandwiched between the solid phase and enzyme-linked antibodies. After incubation, the wells are washed to remove unbound-labeled antibodies. The plate is further detected with HRP luminescent substrate. Luminescence is reported as relative light units (RLUs) on a microplate luminometer. The level of expression for each specific cytokine is directly proportional to the luminescent intensity.

Literature

View user manual